Products » Systems
FOUNDATION WATERPROOFING-VERTICAL SURFACE
1. SUBSTRATE
Typical: concrete screed
- The substrate will be clean, dry, smooth and free from contamination.
2. SEPARATION LAYER (MECHANICAL SECUREMENT ONLY)
Typical: 200-400 g/m² geotextile
-
Install loose, with 100 mm overlap
3.SINTOFOIL MEMBRANE
Typical:ST/Black/1.5mm
-
Any type of Sintofoil membrane (recommended thickness: 1.5 mm min.) is also acceptable.
-
Install with overlap and welded seam as per specifications.^
-
Secure to the substrate:
- by welding to sheet laminated metal strips mechanically secured to the substrate.
- by adhering to the substrate using FB membrane and FB-SF Adhesive.*
* Refer to technical data sheets
^ Refer to "welded seam technology" section
4.PROTECTION LAYER
Typical: 30 mm protection course
-
Install spot-bonded, with butted joints covered by a self-adhesive tape.
5.DRAINAGE LAYER
Typical: 300-500 g/m² geotextile
-
Install loose, with 100 mm overlap.