Norm |
Unit |
UEAtc criteria |
Specifications |
Thickness (1) |
EN 1849-2 |
mm |
± 5% |
1.2 |
Standard roll size |
EN 1848-2 |
m |

|
1.50 x 30 |
Standard colours (2) |
|
|
|
Black - Grey |
Weight per unit area |
EN 1849-2 |
kg/m2 |
± 10% |
1.10 |
Tensile strength L/T |
EN 12311-2 |
N/mm2 |
450
|
600/550 |
Elongation at break L/T (reinforcement) |
EN 12311-2 |
% |
2
|
3 / 3 |
Elongation at break L/T (membrane) |
EN 12311-2 |
% |
- |
700/700 |
Low temperature flexibility |
EN 495-5 |
°C |
-25
|
- 40 |
Dimensional stability L/T |
EN 1107-2 |
% |
- |
0,1 |
Nail tear resistance L/T |
EN 12310-1 |
N |
> 150 |
390/290 |
Static indentation |
EN 12730 |
|
|
|
• Concrete |
|
|

|
20
|
• EPS |
|
|

|
15
|
Dynamic impact |
EN 12691 |
|
|
20
|
Welded seam resistance |
|
|
|
|
• Shear |
EN 12317-2 |
N/50 mm |
Outside seam area |
Pass |
• Peel - average |
EN 12317-1 |
N/50 mm |
150
|
335 |
• Peel - minimum |
EN 12317-1 |
N/50 mm |
80
|
300 |
Hail resistance |
EN 13583 |
m/s |
- |
> 26 |
Durability |
|
|
|
|
• UV resistance - 2.500 hrs |
EN 495-5 |
°C
|
10
|
Pass |
• Heat ageing - Tensile strength L/T |
EN 12311-2 |
%
|
20
|
-5 |
• Heat ageing - Elongation L/T |
EN 12311-2 |
%
|
20
|
-5 |
Wind uplift resistance (MAST fixing) |
UEAtc |
|
|
|
• Wind load (rupture) |
|
|
Pa |
6.000 |
• Permissible load per fixing (B) |
|
|
N |
710 |
Fire rating (FR type) |
PrEN 1187-1 |
|
|
Pass |
Resistance to micro-organisms |
EN ISO 846 |
|
|
Level 2 |
Contact with potable water |
BS 6920 :part 1.7 |
|
|
non toxic |
(1) 1.5mm,1.8mm,2.0mm and other thickness available.
(2) Top ply colour.Bottom ply always black.White,lead grey and other colours available on special order. |