Norm |
Unit |
UEAtc criteria |
Specifications |
Thickness (1) |
EN 1849-2 |
mm |
± 5% |
1.2 |
Roll size |
EN 1848-2 |
m |

|
2.10 x 25 - 1.50 x 30 |
Standard colours (2) |
|
|
- |
Black - Grey |
Weight per unit area |
EN 1849-2 |
kg/m² |
± 10% |
1.08 |
Tensile strength L/T |
EN 12311-2 |
N/mm² |
≥ 6.0 |
18 / 17 |
Elongation at break L/T |
EN 12311-2 |
% |
> 250 |
700 / 700 |
Low temperature flexibility |
EN 495/5 |
°C |
≤ -25 |
- 40 |
Dimensional stability L/T |
EN 1107-2 |
% |
< 1 |
- 0,5 |
Tear resistance L/T |
EN 12310-2 |
N |
≥ |
55/50 |
Water vapour permeability |
EN 1931 |
µ |
+/- 30% |
90.000 |
Static indentation |
EN 12730 |
|
|
|
• Concrete |
|
|
≥ |
L 20 |
• EPS |
|
|
≥ |
L 15 |
Dynamic impact |
EN 12691 |
|
≤ |
| 20 |
Welded seam resistance |
• Shear |
EN 12317-2 |
N/50mm |
Outside seam area |
Pass |
• Peel - average |
EN 12316-2 |
N/50mm |
≥ 150 |
335 |
• Peel - minimum |
EN 12316-2 |
N/50mm |
≥ 80 |
300 |
Hail resistance |
EN 13583 |
m/s |
- |
> 26 |
Durability |
|
|
|
|
• UV resistance - 2.500hrs |
EN 495-5 |
°C
|
≤ 10 |
Pass |
• Heat ageing - Tensile strength L/T |
EN 12311-2 |
%
|
≤ 20 |
- 5 |
• Heat ageing - Elongation L/T |
EN 12311-2 |
%
|
< 20 |
- 5 |
Water absorption |
UEAtc |
% |
< 2 |
<1 |
Wind uplift resistance (MAST fixing) |
UEAtc |
|
|
|
• Wind load (rupture) |
|
Pa |
- |
5.500 |
• Permissible load per fixing (B) |
|
N |
- |
710 |
Fire rating (FR type) wood + min.wool |
PrEN 1187-1 |
|
- |
Pass |
Resistance to micro-organisms |
EN ISO 846 |
|
- |
Level 2 |
Contact with potable water |
BS 6920 :part 1.7 |
|
- |
non toxic |
(1) 1.5mm,1.8mm,2.0mm and other thickness available.
(2) Top ply colour.Bottom ply always black.White,lead grey and other top colours available on special order. |