IPS Logo

Sintofoil ST Membrane
   

Sintofoil ST Membrane

1. DESCRIPTION

TPO/FPA (Flexible Polypropylene Alloy) membrane produced by extrusion of granules resulting from the incorporation of ethylene propylene rubber into a propylene matrix together with other additives as appropriate to the type of membrane.

2. CHARACTERISTICS

Norm

Unit

UEAtc criteria

Specifications

Thickness (1)

EN 1849-2

mm

± 5%

1.2

Roll size

EN 1848-2

m

2.10 x 25 - 1.50 x 30

Standard colours (2)

 

 

-

Black - Grey

Weight per unit area

EN 1849-2

kg/m²

± 10%

1.08

Tensile strength L/T

EN 12311-2

N/mm²

≥ 6.0

18 / 17

Elongation at break L/T

EN 12311-2

%

> 250

700 / 700

Low temperature flexibility

EN 495/5

°C

≤ -25

- 40

Dimensional stability L/T

EN 1107-2

%

< 1

- 0,5

Tear resistance L/T

EN 12310-2

N

55/50

Water vapour permeability

EN 1931

µ

+/- 30%

90.000

Static indentation

EN 12730

 

 

 

• Concrete

 

 

L 20

• EPS

 

 

L 15

Dynamic impact

EN 12691

 

| 20

Welded seam resistance

• Shear

EN 12317-2

N/50mm

Outside seam area

Pass

• Peel - average

EN 12316-2

N/50mm

≥ 150

335

• Peel - minimum

EN 12316-2

N/50mm

≥ 80

300

Hail resistance

EN 13583

m/s

-

> 26

Durability

 

 

 

 

• UV resistance - 2.500hrs

EN 495-5

°C

≤ 10

Pass

• Heat ageing - Tensile strength L/T

EN 12311-2

%

≤ 20

- 5

• Heat ageing - Elongation L/T

EN 12311-2

%

< 20

- 5

Water absorption

UEAtc

%

< 2

<1

Wind uplift resistance (MAST fixing)

UEAtc

 

 

 

• Wind load (rupture)

 

Pa

-

5.500

• Permissible load per fixing (B)

 

N

-

710

Fire rating (FR type) wood + min.wool

PrEN 1187-1

 

-

Pass

Resistance to micro-organisms

EN ISO 846

 

-

Level 2

Contact with potable water

BS 6920 :part 1.7

 

-

non toxic

(1) 1.5mm,1.8mm,2.0mm and other thickness available.
(2) Top ply colour.Bottom ply always black.White,lead grey and other top colours available on special order.

3. FIELDS OF APPLICATION

  • Roofing of non-accessible roofs on various substrates: concrete, steeldeck and wood.
  • Waterproofing of parking decks and garden roofs.
  • Basement tanking and tunnel waterproofing.
  • Lining of ponds,canals,reservoirs and landfills.

4. CHEMICAL RESISTANCE

Sintofoil membrane is of polyolefinic nature i.e. has an intrinsic chemical stability.This implies the membrane can be in contact with many substances of either acid or basic type while maintaining its properties.Long term exposure to highly aggressive agents,especially at elevated temperature, requires a specific case by case evaluation.


5. APPLICATION

  • Sintofoil membranes are installed in compliance with the specifications and details described in the technical manual as published by Imper Italia / Rubberfuse Division.
  • Roofing and waterproofing systems using Sintofoil membranes are installed by applicators trained and approved by the Technical Department of Imper Italia / Rubberfuse Division.